ICU Ventilator
- Home
- ICU Ventilator
Personal Protective Equipment
Laboratory Equipment
Operating Theatre Equipment
This product is intended to provide ventilation assistance and breathing support for adult, pediatric and infant patients.
There are no absolute contraindications for this product. For some special diseases, however, some necessary treatments shall be taken for ventilator mechanical ventilation, or special ventilation modes shall be adopted to prevent possible patient injury.
-Shorter triggering and inspiratory delay
-Powerful non-invasive ventilation
-Compressor Free
-Central Gas Free
-Less cost
-AR-V6 is a fully electronic control ventilator,
-Tidal Volume: 5-2000ml (optional 2-2000ml)
-A wide range of TV adjustments allows the medical team to tailor the ventilator to multiple types/needs of patients, even with NICU patients.
- Invasive Ventilation Modes:
VC-ACV, PC-ACV, PRVC, VC-SIMV, SIMV-PRVC, PC-Dual PAP, PC-APRV, CPAP/PSV, CPAP/VG, AMV/MMV, nCPAP, Apnea Ventilation
- Non-Invasive Ventilation Modes:
PC-ACV, PRVC, SIMV-PRVC, PC-Dual PAP, PC-APRV, nCPAP, CPAP/PSV, CPAP/VG, AMV/MMV, Apnea Ventilation
- HFNC
-Rlung, RSBI, P0.1, PEEPi, V-CO2, PTP, Expiratory Hold, sigh, ATC, PCVR, PPS, Compliance, calibration, O2 suction, 100% O2, and more adding
-Screen Freeze and Lock
-Lung measurement tools: 3 loops;
Departments: ICU, CCU, PACU, NICU, EICU, OR, In-Hospital Transport, etc.
Suitable for:
-Adult and pediatric intensive care
-Neonatal intensive care
-Critical care transport
-Long-term acute care
-Advanced automated adaptive assisted wide-range ventilation system with electronic
microprocessor controlled by volume and pressure to fit for all types of patients from Neonates,
Pediatrics to Adults.
-Both invasive and non-invasive modes make the unit wide applications.
-Integrated self- check system with leak check and system tightness to secure the ventilation
result (POST: Power On self-test).
-Automatic leakage compensation by the unit provides is giving to optimize respirator settings
-Two Lithium batteries guarantee the unit usage up to 6 hours.
-Manual settable Inspiratory pause from 0.1- 6seconds.
-The unit is with automatic triggers adjustment both on flow trigger and pressure trigger.
-The unit is with measurement of volumetric capnography of CO2 (Optional ETCO2 measurement function)
-AMV mode can minimize the work of breathing under the target minute ventilation. (Optional)
SPO2 can directly Visual display the concentration of blood oxygen; lt is an important index to judge the function of ventilation and air change.
The low pressure oxygen interface can be connected to the hyperbaric oxygen cylinder or the central oxygen supply, so that the ventilator can provide sufficient oxygen for patients when ensuring the breathing of mild and severe patients, so as to improve the oxygenation of patients.
The independent low-pressure oxygen interface can be connected to the oxygen pillow or small oxygen bottle to facilitate the hospital transportation and ensure the safety of patients.
The minimum tidal volume is 2ml. It is suitable for newborns and even premature infants to avoid barotrauma;
Meet the needs of patients of different ages, provide individualized treatment, more accurate and safer.
EtCO2 showed the concentration of CO2 in blood during ventilation, reflecting the effect of ventilation; It is an important index to judge hyperventilation or hypoventilation.
Double index real-time monitoring at the same time, more convenient, more intuitive, more secure.