fbpx
Search
Close this search box.
X
  • No products in the list

EMG System AM-AME 6600

AM-AME 6600

EMG System AM-AME 6600

Features
  1. Professional EMG/EP operation platform and perfect test projects, complete each test in the shortest time.
  2. Perfect case report data and graph creating system.
  3. Special database management system.
  4. Select test part with Neuro and muscle navigation system and projects selecting system fleetly and conveniently.
  5. Powerful normal value system, contrast with normal data automatically.
  6. Flexible software design, configure systems according to requirements.
  7. High-speed data collection, electromagnetic interference suppression capability for using high strength and light quality metal enclosure.
  8. Simple and convenient operation panel.
  9. Good Electrostatic and electromagnetic interference suppression capability for using high strength and light quality metal enclosure.
  10. Selectable 1-4 channel input mode meets multi-working modes in clinical EMG test.
  11. High-speed collect and process data with parallel processing technology, display data with graph.
Functions

General electromyogram (EMG),Sensory nerve conductor velocity (SCS),motor nerve conductor velocity (MCS), Fwave, HRe-flex, Blink Reflex, Repetitive nerve stimulation (RNS), Brainstem auditory evoked potential (BAEP),Visual evoked potential (VEP),Somatosensory evoked potentials(SEP)

Technical Specifications

PARAMETER

SPECIFICATION

Computer part
CPU
Intel Pentium III (more than 800MHz)
EMS memory
More than 256M
HD
More than 40G
CD driver
CD-ROM or higher configuration
I/O interface
More than USB2.0 interfaces
Operating system
Windows 7,vista,XP 62bit,32bit
Laser printer
Yes
Main system part
A/D conversion resolution
16Bit
Sampling ratio
200kHz
Analysis time
5-5000ms
Amplifier part
Channel
4
Sensitivity
0.05µV-20mV/Grid
CMRR
≥100dB
Filter frequency
Low-pass:1Hz~3000Hz (-3dB) High-pass:10Hz~20000Hz(-3dB)
Stimulator part
Constant current
0.2-100mA
Pulse width
50-1000µS
Stimulation Frequency
1Hz~5Hz
Stimulation type
Single or continuous stimulation
Protection
Short circuit and overloading protection
Auditory stimulator
Stimulation waveform
40Hz short, Sound stim
Stimulation polarity
Stimulation polarity
Sound intensity
40-120dB (5dB per level)
Frequency of 40Hz carrier wave
500-8000Hz
Visual stimulator
Adopts CRT display whole size
Not less than 200mmx200mm
Mode
Tessellation, horizontal bar and vertical bar
Stimulation view
All-view, half-view and quarter-view
Resolution
3x4,6x8,12x16 ,24x32,48x64
Flash stimulator
All quench, left light, right light, L&R light
Scroll to Top